Landfill Leachate Case Study

The large Landfill now meets discharge permit requirements with a bioFLOW MBR system, achieving over 98% influent parameter removal and generating high-quality effluent.

project

bioFLOW MBR System for New England Landfill

industry

Landfill Leachate

application

Biochemical Oxygen Demand (BOD) Removal | Total Suspended Solids (TSS) Removal | Nitrification of Ammonia

Case study - Waste Management TREE Landfill

Application Parameters

bioprocessH2O is equipped with a team of experts experienced in the wastewater industry. We provide solutions by offering innovative wastewater treatment systems that are custom built to each client’s needs and specifications. Allow bioprocessH2O to help you get the most out of your water with these recommended treatment systems.

Parameter
Influent
Effluent
Wastewater Flow
289,300 GPD
-
BOD
2,093 mg/L
<20 mg/L
TSS
660 mg/L
<10 mg/L
NH4-N
1,483 mg/L
<5 mg/L
FOG
42 mg/L
<10 mg/L

The Problem

The Landfill needed to upgrade their wastewater treatment system to meet the permitted discharge requirements.

The Solution

bioprocessH2O supplied a fully integrated and highly automated bioFLOW MBR System to meet the Local Industrial Discharge Permit requirements.

The Results

The bioFLOW MBR System removes >98% of the influent parameters listed in the table below. The MBR Biological treatment plant provides a robust biological treatment process and effective membrane performance. The bioFLOW MBR System generates a high quality UF permeate that also feeds a RO system for desalination and TOC removal prior to effluent discharge at ≤0.2 NTU and ≤3 SDI.

130,000

GPD

>99%

BOD Removed

>99%

Ammonia-N removed

Speak with a design engineer today.